产品资料

功率探头

如果您对该产品感兴趣的话,可以 sendmsg
产品名称: 功率探头
产品型号: NRP-Z51
产品展商: 德国罗德施瓦茨
产品文档: 无相关文档

简单介绍

无论在实验室还是在生产线,微波功率计R&S NRP都是你正确的选择。新颖的R&S NRP系列功率计的通用性主要归因于新近开发的功率探头。这些探头是智能的独立仪器,他们与基本单元通讯,或经由数字接口与一个pc机通信。现在****实现的智能传感技术,建立了根据通用性和准确性要求的新标准。 如果说功率


功率探头  的详细介绍
  • R&S®NRP-Z R&S®NRP-Z Power Sensors
    Power Sensors

    For operation with R&S®NRP2 base unit or via USB on a Laptop/PC

     

     

Three-Path Diode Power Sensors
  • R&S®NRP-Z11  R&S®NRP-Z11 Three-Path Diode Power Sensors
    Three-Path Diode Power Sensors

    Fast, accurate and packed with features for CW and modulated signals

    Measurement range: -67 dBm to +23 dBm,
    Frequency range: 10 MHz to 8 GHz,
    N connector

     

     

  • R&S®NRP-Z21 R&S®NRP-Z21 Three-Path Diode Power Sensors
    Three-Path Diode Power Sensors

    Fast, accurate and packed with features for CW and modulated signals

    Measurement range: -67 dBm to +23 dBm,
    Frequency range: 10 MHz to 18 GHz, 
    N connector

     

     

  • R&S®NRP-Z22  R&S®NRP-Z22 Three-Path Diode Power Sensors
    Three-Path Diode Power Sensors

    Fast, accurate and packed with features for CW and modulated signals

    Measurement range: -57 dBm to +33 dBm, 
    Frequency range: 10 MHz to 18 GHz, 
    N connector

     

     

  • R&S®NRP-Z23  R&S®NRP-Z23 Three-Path Diode Power Sensors
    Three-Path Diode Power Sensors

    Fast, accurate and packed with features for CW and modulated signals

    Measurement range: -47 dBm to +42 dBm, 
    Frequency range: 10 MHz to 18 GHz, 
    N connector

     

     

  • R&S®NRP-Z24 R&S®NRP-Z24 Three-Path Diode Power Sensors
    Three-Path Diode Power Sensors

    Fast, accurate and packed with features for CW and modulated signals

    Measurement range: -42 dBm to +45 dBm, 
    Frequency range: 10 MHz to 18 GHz, 
    N connector

     

     

  • R&S®NRP-Z31 R&S®NRP-Z31 Three-Path Diode Power Sensors
    Three-Path Diode Power Sensors

    Fast, accurate and packed with features for CW and modulated signals

    Measurement range: -67 dBm to +23 dBm, 
    Frequency range: 10 MHz to 33 GHz, 
    3.5 mm connector

     

     

     

Two-Path Diode Power Sensors
  • R&S®NRP-Z211 R&S®NRP-Z211 Two-Path Diode Power Sensors
    Two-Path Diode Power Sensors

    Cost-effective power measurement solution for production

    Measurement range: -60 dBm to +20 dBm, 
    Frequency range: 10 MHz to 8 GHz, 
    N connector

     

     

  • R&S®NRP-Z221  R&S®NRP-Z221 Two-Path Diode Power Sensors
    Two-Path Diode Power Sensors

    Cost-effective power measurement solution for production

    Measurement range: -60 dBm to +20 dBm, 
    Frequency range: 10 MHz to 18 GHz, 
    N connector

     

     

     

Thermal Power Sensors
  • R&S®NRP-Z51  R&S®NRP-Z51 Thermal Power Sensor
    Thermal Power Sensor

    Most accurate power measurements for reference applications and use in calibration labs

    Measurement range: -30 dBm to +20 dBm, 
    Frequency range: DC to 18 GHz,
    N connector

     

     

  • R&S®NRP-Z52  R&S®NRP-Z52 Thermal Power Sensor
    Thermal Power Sensor

    Most accurate power measurements for reference applications and use in calibration labs

    Measurement range: -35 dBm to +20 dBm, 
    Frequency range: DC to 33 GHz,
    3.5 mm connector

     

     

  • R&S®NRP-Z55  R&S®NRP-Z55 Thermal Power Sensor model .03
    Thermal Power Sensor model .03

    Most accurate power measurements for reference applications and use in calibration labs

    Measurement range: -35 dBm to +20 dBm, 
    Frequency range: DC to 40 GHz, 
    2.92 mm connector

     

     

  • R&S®NRP-Z55  R&S®NRP-Z55 Thermal Power Sensor model .04
    Thermal Power Sensor model .04

    Most accurate power measurements for reference applications and use in calibration labs

    Measurement range: -35 dBm to +20 dBm, 
    Frequency range: DC to 44 GHz, 
    2.92 mm connector

     

     

  • R&S®NRP-Z56  R&S®NRP-Z56 Thermal Power Sensor
    Thermal Power Sensor

    Most accurate power measurements for reference applications and use in calibration labs

    Measurement range: –35 dBm to +20 dBm, 
    Frequency range: DC to 50 GHz, 
    2.4 mm connector

     

     

  • R&S®NRP-Z57 R&S®NRP-Z57 Thermal Power Sensor
    Thermal Power Sensor

    Most accurate power measurements for reference applications and use in calibration labs

    Measurement range: –35 dBm to +20 dBm, 
    Frequency range: DC to 67 GHz, 
    1.85 mm connector

     

     

  • R&S®NRP-Z58   R&S®NRP-Z58 Thermal Power Sensor
     
    Thermal Power Sensor

    Most accurate power measurements for reference applications and use in calibration labs

    Measurement range: –35 dBm to +20 dBm, 
    Frequency range: DC to 110 GHz, 
    1.00 mm connector

     

     

     

Wideband Power Sensors
  • R&S®NRP-Z81 R&S®NRP-Z81 Wideband Power Sensor
    Wideband Power Sensor

    Time domain analysis and automatic pulse analysis for radar applications and universal use

    Measurement range: -60 dBm to +20 dBm, 
    Frequency range: 50 MHz to 18 GHz,
    N connector

     

     

  • R&S®NRP-Z85 R&S®NRP-Z85 Wideband Power Sensor
    Wideband Power Sensor

    Time domain analysis and automatic pulse analysis for radar applications and universal use

    Measurement range: -60 dBm to +20 dBm, 
    Frequency range: 50 MHz to 40 GHz,
    2.92 mm connector

     

     

  • R&S®NRP-Z86  R&S®NRP-Z86 Wideband Power Sensor
    Wideband Power Sensor

    Time domain analysis and automatic pulse analysis for radar applications and universal use

    Measurement range: -60 dBm to +20 dBm,
    Frequency range: 50 MHz to 40 GHz,
    2.4 mm connector

     

     

     

Average Power Sensors
  • R&S®NRP-Z91 R&S®NRP-Z91 Average Power Sensor
    Average Power Sensor

    Accurate average power measurements for EMC applications

    Measurement range: -67 dBm to +23 dBm, 
    Frequency range: 9 kHz to 6 GHz, 
    N connector

     

     

  • R&S®NRP-Z92 R&S®NRP-Z92 Average Power Sensor
    Average Power Sensor

    Accurate average power measurements for EMC applications

    Measurement range: -57 dBm to +33 dBm,
    Frequency range: 9 kHz to 6 GHz, 
    N connector

     

     

     

Level Control Sensors
  • R&S®NRP-Z28 R&S®NRP-Z28 Level Control Sensor
    Level Control Sensor

    Highly accurate signal level generation in conjunction with a signal generator

    Measurement range: -67 dBm to +20 dBm, 
    Frequency range: 10 MHz to 18 GHz, 
    N connector

     

     

  • R&S®NRP-Z98  R&S®NRP-Z98 Level Control Sensor
    Level Control Sensor

    Highly accurate signal level generation in conjunction with a signal generator

    Measurement range: -67 dBm to +20 dBm, 
    Frequency range: 9 kHz to 6 GHz, 
    N connector

     

     

     

Power Sensors for other R&S instruments
  • R&S®NRP-Z27  R&S®NRP-Z27 Power Sensor Module (for use with R&S®FSMR)
    Power Sensor Module (for use with R&S®FSMR)

    Level calibration of signal sources in conjunction with the R&S®FSMR measurement receiver

    Measurement range: -24 dBm to +26 dBm, 
    Frequency range: DC to 18 GHz, 
    N connector

     

     

  • R&S®NRP-Z37 R&S®NRP-Z37 Power Sensor Module (for use with R&S®FSMR)
    Power Sensor Module (for use with R&S®FSMR)

    Level calibration of signal sources in conjunction with the R&S®FSMR measurement receiver

    Measurement range: -24 dBm to +26 dBm, 
    Frequency range: DC to 26.5 GHz, 
    3.5 mm connector